Bio-Signal Acquisition and Processing Using Labview Essay Sample free essay sample

Abstraction: The increased public presentation of personal computing machines and their reduced cost has made it possible for development of Personal computer based signal processing systems. Hospitals need several measurement systems that can mensurate physiological parametric quantities of the patients. Although diagnostic medical instruments have been widely used. uniting practical instrument engineering to accomplish the intent of physiological measuring has several benefits. These systems are efficient and cost-efficient for geting and analysing biomedical signals. Using practical instrumentality to accomplish physiological measuring will mostly diminish the cost and increase the flexibleness of the instruments. This workaims at planing a practical instrument for geting and processing of Electrooculogram signal. Electrooculography ( EOG ) is a technique for mensurating the resting potency of the retina. Keywords: Data acquisition. signal processing. LabVIEW. Virtual Instrument. EOGmeasurement I. INTRODUCTION Hospitals need several measurement systems that can mensurate physiological parametric quantities of the patient. Measurement systems should be able to mensurate accurately the vital organs of patient like bosom conditions. organic structure temperature. electrical activity of the bosom. electrical activity of the encephalon etc. This information should be readily available to the physicians for diagnosing and proper intervention. PCbased signal acquisition. and analysis is an efficient and cost effectual method forbiomedical signal acquisition and monitoring. Isolation of the topic from the electronic circuitry is really of import. Besides. since the bio signal degree is really low. elaboration of signals is of import. Hence. a Personal computer based system consists of extra circuits for isolation and elaboration of the signals. Uniting practical instrumentality engineering for physiological measurings is an approaching engineering that is presently lifting up at a faster rate. The cost can be drastically brought down and the flexibleness can be increased by usage of practical instrumentality. National Instrument’s LabVIEWis a platform and development environment for a ocular scheduling. The intent of such scheduling is automatizing the use of processing and mensurating equipment in any laboratory apparatus. Controls and indexs on the front panel allow an operator to input informations into or pull out informations from a running practical instrument. A cardinal benefit of LabVIEW over other development environments is the extended support for accessing instrumentality hardware. The paper is organized as follows: Section I. gives debut to practical instrumentality and demand of the current work. Section II. explains the bio signal inside informations. Section III discusses the challenges in the design. Section IV explains the public presentation and consequences. and the last Section V concludes the paper followed by mentions used. II. BIOELECTRIC SIGNAL- . ELECTOOCULOGRAM Electric potencies are generated as a consequence of motion of the orbs within the conductive environmentof the skull. Electrodes placed on either sideof the eyes or above and below them pick up th e potencies generated by the gesture of the orb. This possible varies about in proportion to the motion of the orbs. This signal is little individually. This requires five electrodes which are placedabove and below the oculus for perpendicular motions. and on the sides of the oculus ( canthi ) for horizontal motions. A mention electrode is placed on the brow of the topic. Sing the cost and dependability makes Silver ( Ag ) -Silver Chloride ( AgCl ) electrodes ideal for EOG. An electrolytic gel based on Na chloride is applied to the tegument since the upper beds of the tegument are hapless music directors of electricity. Several methods have been proposed in literature that use Electrooculograms ( EOGs ) happening as a consequence of oculus motions [ 3 ] [ 5 ] . An electric wheelchair controlled by oculus motions utilizing EOG has been developed as a motion support device. An EOG based infirmary dismay system has been successfully tested. An oculus gazing system for observing any point where the oculus gazes on the screen has been developed for communicating aid intents [ 4 ] . [ 5 ] . III. CONSTRUCTION AND CHALLENGES The chief aim of the current work carried on is to develop a practical instrument which can get the EOG signal. execute noise riddance and elaboration. Geting the signal utilizing NI DAQ. planing the suited low cost amplifier for elaboration and designing of low base on balls and high base on balls filters was done. The acquired signal was displayed utilizing LabVIEW front panel. The front panel and block diagram have been designed. The basic block diagram is shown is fig 1. Noise DecreaseEOG signals have a scope of 0. 5Hz to 30Hz. Therefore. a low base on balls filter with 30Hz cutoff could take most of the high frequence noises. And a high base on balls filter of 0. 5 Hz is required. which together form a set base on balls of 50 Hz. Other noise artefacts are largely transients caused. for illustration. by the turning of an electrical switch on/off in the locality of the electrodes. contraction of the facial or neck musculuss. slippage of Fig. 1 System Organization filter of bandwidth 0. 5Hz to 30 Hz. Power line frequence can be easy removed. utilizing a notch filter the electrode due to sudate and oculus eye blink. However. the signals produced by oculus water chickweeds are. in fact. rather regular. They appear as sudden spikes with separating amplitudes. Hence it is possible to easy acknowledge. changedwhen the oculus is moved and the motion of theeye is translated into electrical alteration ofpotential. This possible can be noninvasively recorded by utilizing surface electrodes. provides anoninvasive method for entering full scope ofeye motions. The resting potency is A brace of electrodes is required for measuringthe resting potency of the retina. It Hz ) . Electrooculography is a technique for ( 10 to 100microV ) and has low frequences ( District of Columbia to 30 ? Fig. 1. Block diagram of EOG Amplifier electrooculography under certain conditions do non damage it. Preamplifier: The input preamplifier phase carries out the initial elaboration of the EOG. This phase should hold really high input electric resistance and a high common-mode-rej ection ratio ( CMRR ) . Isolation circuit: The circuitry of this block contains a barrier to the transition of current from the power line ( 50 Hz ) . This barrier would forestall unsafe currents from fluxing from the patient through the amplifier to the land of the recording equipment or personal computer. Driver amplifier: Circuitry in this block amplifies the EOG to a degree at which it can suitably enter the signal on the recording equipment. This phase besides carries out the bandpass filtering of the electrocardiograph to give the frequence features of the signal. Case construction: Merely one subdiagram is seeable at a clip. and the construction executes merely one instance at a clip. An input value determines which subdiagram executes. Time hold: The Wait ( MS ) map delaies until the msec counter counts to an sum equal to the input you specify. This map guarantees that the loop executing rate is at least the sum of the input you specify. Filter: The Filter Express VI processes a signal through filters and Windowss. Filters used include the undermentioned: Highpass. Lowpass. Bandpass. Bandstop. and Smoothing. Windows used include Butterworth. Chebyshev. Inverse Chebyshev. Elliptical. and Bessel. Waveform graph: The wave form graph displays one or more secret plans of equally sampled measurings. Amplitude and degree measurings: he Amplitude and Level Measurements Express VI performs electromotive force measurings on a signal. These include DC. rms. maximal extremum. minimal extremum. extremum to top out. rhythm norm. and rhythm rms measurings. Tone measurings: The Tone Measurements Express VI hunts for a individual tone with the highest frequence or highest amplitude. It besides finds the frequence and amplitude of a individual tone. Write to measurement file: The Write to Measurement File Express VI writes a file in LVM or TDM file format. Build tabular array: Converts a signal or signals into a tabular array of informations that lists the amplitude of each signal and the clip informations for each point in the signal. Result tabular array: Use the tabular array control to make a tabular array on the front panel. Each cell in a tabular array is a twine. and each cell resides in a column and a row. Therefore. a tabular array is a show for a 2D array of strings. A. Signal Acquisition and treating Data acquisition cards for multiple channels for parallel input and end products are available. Using the libraries. plans for the informations acquisition are rapidly and easy made. Extra noise is filtered utilizing the pick of filters like Butterworth. Bessel. Chebyshev I. and Chebyshev II provided in the LabVIEWsoftware. The installing of the DAQ card includes: 1. Installation of the application package 2. Installation of the DAQ card driver foremost. before piecing DAQ card into the desktopcomputer. This procedure can guarantee WINDOWS to observe the DAQ card. 3. Installing the necessary devices. accoutrements and overseas telegrams. 4. Power on the computing machine. 5. Confirm that the device is recognized. 6. Run the trial Panel. In the current work. M Series USB-6221 is used as informations acquisition interface. 5. String: A twine is a sequence of displayable or non-displayable ASCII characters. String sections provide a platformindependent format for information and information. into its frequence constituents. One of the most common manner to make this is with an FFT. In order to ease this type of analysis. LabVIEW comes with built in FFTs that make the procedure of constituent separation quick and easy. Digital filters are provided with the pick of Butterworth. Bessel. Chebyshev and digital filters. With a few accommodations these filters can be configured for about any design that is needed. While cringle: Repeats the sub-diagram inside it until the conditional terminus. an input terminus. receives a peculiar Boolean value. Merge signal: Merges two or more signals into a individual end product. Resize the map to add inputs. This map appears on the block diagram automatically when you wire a signal end product to the wire subdivision of another signal. Simulate signal: The Simulate Signal Express VI generates simulated informations such as a sine moving ridge. Numeric control A ; index: The numeral informations type can stand for Numberss of assorted types. such as whole number or existent. The two common numeral objects are the numeral control and the numeral index. ( courtesy: National Instruments. LabVIEW ) The Fast Fourier Transform ( FFT ) and the power spectrum are powerful tools for analysing and mensurating signals from plug-in informations acquisition ( DAQ ) devices. We can efficaciously get time-domain signals. step the frequence content. and change over the consequences to real-world units and shows as shown on traditional bench top spectrum and web analysers. Since the signal of involvement is continuously changing non stationary signal. Wavelet transform block has been included. The ripple transform is a mathematical tool that decomposes a signal into a representation that shows signal inside informations and tendencies as a map of clip. The chief advantages of ripple methods over traditional Fourier methods are the usage of localised footing maps and the faster calculation velocity. A. Design Considerations The work undertaken involves 4 phases which are discussed as below. The first phase is choice of the electrodes. The electrodes were chosen with the concern of protecting the eyes from risky elements. IV. RESULTS AND DISCUSSIONS The biomedical signals acquired from the human organic structure are often really little. frequently in the millivolt/microvolt scope. and each has its ain processing demands. Electrooculography signals are in the microvolt scope and have many frequence constituents. These biomedical signals require treating before they can be analyzed. LabVIEW contains the tools. from fast Fourier transforms to digital filters to recognize complex analysis. In order to make frequence analysis. a complex signal must foremost be broken down Fig. 3 Design of the block diagram B. Design Considerations The work undertaken involves 4 phases which are discussed as below. The first phase is choice of the electrodes. The electrodes were chosen with the concern of protecting the eyes from risky elements. Silver/Silver-Chloride electrodes were chosen because the half-cell potency was the closest to zero. Electrodes with the smallest sum of halfcell potency are desirable because they cause the Stages 2 and 3 encompass the sensing of horizontal and perpendicular motions of the oculus. severally. The 2nd phase ( for horizontal favoritism ) detects sidelong motions at the fringe of each oculus. The hardware in this phase consists of the EOG biopotential amplifier. Similarly. the 3rd phase ( for perpendicular favoritism ) consists of another EOG biopotential amplifier. Location of the electrodes is shown in figure 3. When the eyes look consecutive in front. a steady dipole is created between the two electrodes. When the regard is shifted to the left. the positive cornea becomes closer to the left electrode. which becomes more positive. The undermentioned public presentation least sum of beginning. By definition. the H electrode has a zero half-cell potency. but due to the gaseous nature. they can non be practicably used. Although lead electrodes have a lower half-cell potency than the Ag/Ag-Cl electrodes. lead is risky to the wellness and therefore is avoided. Thus my pick of electrodes takes into history an optimum degree of safety ordinances and preciseness ( least offset ) . LabVIEW is necessary to change over the signal obtained by the EOG into explainable informations for directional favoritism. Furthermore. a graphical show will be implemented in LabVIEW to imitate the motion of an icon on the computing machine screen. Figures 5 shows the water chickweeds. figures 6 and 7 shows the perpendicular motions and figure 8 displays the horizontal motion of the eyes captured by the designed informations acquisition system and displayed by the front panel. The figure4 shows the hardware apparatus. Therefore by puting electrodes to the left and right and above and below the oculus. horizontal and perpendicular motions can be obtained. The end product of the 2nd and 3rd phase is inputted into the concluding phase. the LabVIEW informations acquisition package tool and the personal computing machine. The choice of LabVIEW over diminishing. This has facilitated the development Personal computer based signal acquisition and analysis systems. These systems can replace dearly-won stand-alone systems that are presently in usage. Thecomponents necessary for a LabVIEW based acquisition and analysis system areinexpensive. and readily available. Here. the initial demands of a Personal computer based biosignal acquisition and treating systems have been studied and reviewed. Developing Personal computer based systems utilizing LabVIEW is an efficient option to stand entirely systems. EOG amplifier was designed. The information acquired was amplified. filtered and observed on the front panel. Both the horizontal and perpendicular motion of the eyes and oculus water chickweeds were visualized. The writers wish to reason that the system developed has certain restrictions in footings of truth and characteristics. There is batch of range for future betterment of the developed system. ACKNOWLEDGMENT The writers wish to thank the section caput. laboratory staff. Institutional LabVIEW Academy. at college Innovation Centre for allowing to carry on the experiment and besides thankful to all the topics who have cooperated in the experiment. Mentions [ 1 ] . Parten. M. ( 2003 ) . Using practical instruments in ameasurements research lab. Proceedings of the 2003 AmericanSociety for Engineering Education Annual Conference A ; Exposition. June 22-26. 2003. [ 2 ] . MrinalTrikhal. Tapan Gandhi. AyushBhandari. and Vijay Kharel. ‘Multiple Channel Electrooculogram Classification utilizing Automata’ . International Workshop on Medical Measurements and Applications. – 2007. [ 3 ] R. Barea. L. Bosquete. M. Mazo. and E. Lopez. â€Å"System for aided mobility utilizing oculus movementsbased on electrooculography. † IEEE Trans. Rehab. Eng. . vol. 10. no. 4. pp. 209-217. 2002. [ 4 ] J. Gips and P. Olivieri. â€Å"Eagle Eyess: An oculus control system for individuals with disablements. † 11th Int. Conf. Tech. Persons Disabilities. Mar. 1996. [ 5 ] Y. Kuno. T. Yagi. I. Fujii. K. Koga. and Y. Uchikawa. â€Å"Development of eye-gaze input interface usingEOG. † Trans. Inf. Processing Soc. Jap. . vol. 39. no. 5. pp. 1455-1462. May 1998. [ 6 ] T. Gandhi. M. Trikha. J. Santosh and S. Anand. â€Å"VHDL Based Electro-Oculogram Signal Classification† . 15th International Conference on Advanced Computing and Communications 2007. IEEE computing machine Society. [ 7 ] AysegulGuven. Sadik Kara. â€Å"Classification of electrooculogram signals utilizing unreal nervous network† . Adept systems with Applications. 31 ( 2006 ) 199-205. Elsevier. . [ 8 ] B. Grinstead. M. E. Parten ; Biomedical signal acquisition utilizing â€Å"Labview† . Computer-Based Medical Systems. 1998. Proceedings. 11th IEEE Symposium on ; pp: 157 – 161 ; ISSN: 1063-7125. [ 9 ] Geddes. L. A. . ‘Principles of applied biomedical instrumentation’ . Wiley. New York. 1989. [ 10 ] . J. G. Webster. ‘Medical Instrumentality: Application and Design’ . 3rd Ed. New York: John Wiley A ; Sons. Inc. . 1998. Biography Patterson is a pupil of Masterss in control systems under the section of Instrumentation and Control Engineering. His major involvements are in the field of practical instrumentality and control Engineering. Sandra D’Souza. is a module of the section of instrumentality and control Engineeringand a research bookman in the country of biomedical signal processing. Her major involvements are in the field of digital signal processing and bio signal processing.

No comments:

Post a Comment

Note: Only a member of this blog may post a comment.